C-Bus
|
Compatible with addition of interface
|
|
Clearance Needed Above Framework
|
90mm
|
|
Colorbond Cappings
|
Are included in every installation
|
|
Colorbond Coating
|
80 or 25% depending on colour choice
|
|
Colorbond Flashings
|
Wall, gutter and under flashings are standard issue
|
|
Curved Beams
|
Available and dependant on spanning requirements
|
|
Electrical Requirements
|
10A Standard GPO
|
|
Frame - Custom
|
Available and dependant on spanning requirements
|
|
Frame Steel - Standard
|
250 x 75 "C" Section Purlin
|
|
Frame Timber - Standard
|
250 x 50 KDT
|
|
Gutter - Vergola
|
- 245-195 deep tapered gutter system
- 150mm wide
- 45mm high
- 30mm squash fold
|
|
Louvre Endcap Material
|
Non corrosive alloy
|
|
Louvre Material
|
XRW or XSE .42 BMT Zincalume with Colorbond Coating
|
|
Louvre Linkage
|
Solid alloy bar
|
|
Louvre Maximum Span
|
3600mm
|
|
Louvre Water Clearance
|
1 degree fall is applied to the louvre
|
|
Louvre Cover
|
200mm
|
|
Mass Weight
|
- Louvre span up to 2600mm / 10kg m2
- Louvre span 2600mm to 3000mm / 11.6kgm2
- Louvre Span 3000mm to 3600mm / 16.5kgm2
- 250 x 75 "C" Section Framing / 8.17kg plm
|
|
Operation
|
12V Heavy duty lineal actuator motor / max 25 louvres
|
|
Rotation
|
0-150 degrees
|
|
Sensor
|
- Moisture detector acting as rain sensor
- Smoke alert sensor
|
|
Wind Testing
|
Tested to withstand cyclonic conditions - 43m per second
|
|
Wiring Requirements
|
- Switch drop from processor / flat 8 strand data cable
- Connection to rain sensor / 1.5mm2 twin
- Connection to motor / 1.5mm2 twin minimum
|
|
Storm Water
|
stormwater connection is needed.
|